精品视频1区2区3区,91国在线啪精品一区,精品免费人伦一区二区三区蜜桃 ,九九视频这里只有精品99,成人区人妻精品一区二区三区 ,全部av免费在线播放 ,影音先锋男人av橹橹色,亚洲小说图区综合在线
        或者

        深圳市中天檢測技術有限公司

        檢測認證人脈交流通訊錄
        • 深圳電視機ISTA1A測試包裝件ISTA1A報告最權威第三方測試報告

        • 這真不是您需要的服務?

           直接提問 | 回首頁搜

        • 對應法規:ISTA 1A
          CNAS認可項目:是
        •  

           

          深圳電視機ISTA1A測試包裝件ISTA1A報告最權威第三方測試報告

           

           

          ISTA, Distributing Confidence, Worldwide™
          ISTA 1 Series are the most basic category of performance tests.
          • They challenge the capability of the package and product to withstand transport hazards, but
          • They are not simulations of actual transport hazards, and
          • Do not necessarily comply with carrier packaging regulations.
          When properly applied, ISTA procedures will provide tangible benefits of:
          • Shortened packaged development time and confidence in product launch
          • Protection of products and profits with reduced damage and product loss
          • Economically balanced distribution costs
          • Customer satisfaction and continued business.
          There are three sections: Overview, Testing and Report
          • Overview provides the general knowledge required before going into the testing laboratory and
          • Testing presents the specific instructions to do the testing in the laboratory and
          • Report indicates what data shall be recorded to submit a test report to ISTA.
          Two systems of weights and measures are presented in ISTA test procedures. They are the English system (Inch-Pound) and the
          international system SI (Metric). Inch-Pound units are shown first with Metric units in brackets, except in some tables where they
          are shown separately.
          • Either system may be used as the unit of measure (standard units), but
          • The standard units chosen shall be used consistently throughout the procedure.
          • Units are converted to two significant figures and
          • Not exact equivalents.
          VERY IMPORTANT:
          The entire document shall be read and understood before proceeding with a test.
          OVERVIEW OF PROCEDURE 1A
          Test Procedure 1A is an integrity test for individual packaged-products.
          • It can be used to evaluate the performance of a packaged-product.
          • It can be used to compare relative performance of package and product design alternatives.
          • The package and product are considered together and not separately.
          • Some conditions of transit, such as moisture, pressure or unusual handling, may not be covered.
          Other ISTA Procedures may be appropriate for different conditions or to meet different objectives.
          Specific suggestions:
          • To use random vibration instead of fixed displacement vibration, use ISTA Test Procedure 1G and not 1A.
          • For packaged-products where a minimum compression value should be tested, use ISTA Test Procedure 1C.
          • For packaged-products intended for international distribution consider ISTA Partial-Simulation Performance Test Procedure
          2A.
          • For packaged-products that may be transported in a small parcel delivery system consider ISTA General Simulation
          Performance Test Procedure 3A.
          Refer to Guidelines for Selecting and Using ISTA Procedures and Projects for additional information.
          ISTA 1 Series
          Non-Simulation
          Integrity
          Performance
          Test Procedure
          VERSION
          DATE
          Last TECHNICAL
          Change:
          JANUARY 2001
          Last EDITORIAL
          Change:
          JANUARY 2008
          For complete
          listing of
          Procedure
          Changes and
          Version Dates
          go to
          www.ista.org
          Preface
          ISTA 1A 2001 - Page 2 of 8
          © 2008 International Safe Transit Association. All rights Reserved.
          1A OVERVIEW OF PROCEDURE 1A
          Test Procedure 1A covers testing of individual packaged-products weighing 150 lb (68 kg) or less when prepared for shipment.
          EXCEPTION:
          Individual packaged-products on a visible skid or pallet and that weigh more than 100 lb (45 kg) may be tested according to Test
          Procedure 1B or 1E.
          The shipper shall determine the following prior to testing:
          • what constitutes damage to the product and
          • what damage tolerance level is allowable, if any, and
          • the correct methodology to determine product condition at the conclusion of the test and
          • the acceptable package condition at the conclusion of the test.
          For additional information on this determination process refer to Guidelines for Selecting and Using ISTA Procedures and Projects.
          Samples should be the untested actual package and product, but if one or both are not available, the substitutes shall be as
          identical as possible to actual items.
          Number of samples required:
          • One sample is required for the tests in this procedure.
          Replicate Testing Recommended:
          To permit an adequate determination of representative performance of the packaged-product, ISTA:
          • Requires the procedure to be performed one time, but
          • Recommends performing the procedure five or more times using new samples with each test.
          NOTE:

           

          深圳電視機ISTA1A測試包裝件ISTA1A報告最權威第三方測試報告

          Packages that have already been subjected to the rigors of transportation cannot be assumed to represent standard conditions. In
          order to insure testing in perfect condition, products and packages shipped to certified laboratories for testing must be:
          • over-packaged for shipment to the laboratory or
          • repackaged in new packaging at the laboratory.
          The tests shall be performed on each test sample in the sequence indicated in the following table:
          Sequence # Test Category Test Type Test Level For ISTA Certification
          1 Vibration Fixed Displacement
          1 in (25mm) peak-to-
          peak at a frequency to be
          determined
          Required
          Drop
          Height varies with
          packaged-product weight
          Incline-Impact (Conbur) Impact Velocity varies
          with packaged-product
          weight
          2 Shock
          (Alternative methods
          allowed – select one
          test type)
          Horizontal Impact
          Impact Velocity varies
          with packaged-product
          weight
          Required
          Scope
          Product Damage
          Tolerance and
          Degradation
          Allowance
          Samples
          Test Sequence
          ISTA 1A 2001 - Page 3 of 8
          © 2008 International Safe Transit Association. All rights Reserved.
          1A EQUIPMENT REQUIRED FOR PROCEDURE 1A
          Fixed Displacement Vibration Test:
          • Vibration Test System with a 1 in (25 mm) fixed or controlled displacement complying with Method A1 or A2 of the
          apparatus section of ASTM D 999-01.
          Rotary or vertical linear motion of the platform is acceptable.
          • Metal shim 0.06 in (1.5 mm), thick approximately 2 in (50 mm) wide and at a convenient length.
          • Tachometer or suitable indicator for determining vibration frequency in cycles per second (Hz) or cycles per minute
          (CPM).
          • Automatic timer or stopwatch.
          The following alternatives are acceptable for the equipment required for the Shock Test:
          Type of Shock Test Type of Equipment In compliance with the apparatus section of …
          Drop Test
          Free fall drop tester ASTM D 5276-98
          Vertical Shock Test
          Shock test machine
          ASTM D 5487-98(02)
          Alternative Incline Test
          Incline impact tester (conbur)
          ASTM D 880-92(02)
          Alternative Horizontal Test
          Horizontal impact test system
          ASTM D 4003-98

           

           

           

          深圳電視機ISTA1A測試包裝件ISTA1A報告最權威第三方測試報告

           

           

          出口美國需要做ISTA測試,可拿到美國發的證書。時間和價格都優勢。


        • 檢測通手機版

        • 檢測通官方微信

        •  檢測通QQ群